Backflow Preventer Freeze Protection: How to Insulate and Drain It

The pressure vacuum breaker on your sprinkler line is the most exposed part of the system. How to protect it through a High Desert winter, with the drain steps from the FEBCO and Zurn Wilkins manuals.

Get a Free Irrigation Estimate
Reviewed by Freddie Ruiz, Owner and CSLB-licensed contractor License C-27 #957605 Building landscapes in the High Desert since 2009 Last updated

The surest way to protect a sprinkler backflow preventer from freezing is to drain it before the first hard freeze and leave its valves and test cocks half open for the winter. Insulation helps, and it is the right move if you keep watering in winter, but FEBCO says its 765 must be drained for the winter where freezing may occur. Whatever you use, never cover the air vent.

If your sprinkler line has a pressure vacuum breaker (PVB) or similar backflow preventer standing above ground, it sits in the open, full of water, on nights that reach 20°F or colder in about 6 of 10 years at Victorville and 7 of 10 years at El Mirage (NOAA 1991-2020 normals). Water expands about 9% when it freezes (USGS), and the brass body and bonnet have nowhere to give.

This page covers insulation first, then the manufacturer drain steps for two pressure vacuum breakers: the FEBCO 765 and the Zurn Wilkins 720A. Other models differ, so read your model plate before you touch a valve.

Why Backflow Preventers Freeze in the High Desert

Freeze risk depends a lot on where you live. NOAA’s normals show about 32 nights a year at or below 32°F at the Hesperia 2E station, about 54 at Victorville, and about 70 at El Mirage on the west side (NOAA NCEI). The median first freeze is November 11 at Victorville, November 12 at El Mirage and December 1 at Hesperia 2E.

The manufacturers are clear about the risk. Zurn’s instructions for the Wilkins 720A say the PVB may be installed outdoors only if the device is protected against any freezing conditions, and that the installation location must be kept above 32°F (Zurn Wilkins 720A). FEBCO’s winterization sheet says its assemblies must be drained for the winter in areas where freezing temperatures may occur (Watts/FEBCO 765). The City of Hesperia lists irrigation control valves among the pipes at risk each winter (City of Hesperia).

First, Check the Model Plate

Drain valve positions, numbering and parts differ by model, and by how the installer plumbed your line. Look for the maker and model cast or stamped on the body or on a tag before you follow any steps.

What the plate saysWhat to do
FEBCO 765Follow the FEBCO 765 steps below and the Watts winterization sheet.
Zurn Wilkins 720AFollow the Wilkins 720A steps below and the Zurn instructions.
Rain Bird PVBDiscontinued. A backflow parts seller lists it as produced from 1982 to 1993 (backflowparts.com), and we found no current Rain Bird manual for it. Rain Bird’s current residential backflow-type product is the ASVF anti-siphon valve (Rain Bird). The drain logic on older PVBs is similar to the two models here, but without a manual, call an irrigation pro before you take one apart.
Anything elseFind that maker’s installation or winterization sheet by model number, or have a pro look at it.

Insulating a Backflow Preventer

Insulation slows heat loss. It does not make a full, undrained device freeze-proof, which is why FEBCO and Zurn both talk about draining. Insulation makes sense in two cases: over a drained device as extra protection, and on a device you keep in service because you water in winter.

  • Rain Bird: insulate backflow preventers and valves if they are above ground, without blocking the air vents and drain outlets on backflow preventers. Wrap above-ground pipe with foam insulation tape and a plastic bag (Rain Bird).
  • Zurn: do not block the air vent opening with insulation (Wilkins 720A).
  • City of Hesperia: heat tape wrapped around exposed pipes and plugged into an outside outlet, insulation on exterior supply risers, and an insulated cover over control valves, such as a wooden box lined with insulation (City of Hesperia).

Store-bought insulated covers and bags work on the same idea. Cover ratings vary by product, so do not assume any cover protects to a given temperature unless the maker says so for your size and model.

How to Drain a FEBCO 765 for Winter

From the Watts/FEBCO 765 winterization instructions (IS-F-765). Letters match the valve labels in that sheet. Two notes come first in the manual: the assembly can not be adequately drained through the testcocks, and drain valves must be installed on the inlet and outlet sides below the assembly.

  1. Turn off the main shut-off valve (A) supplying the system.
  2. Open all inlet and outlet drain valves (B and E). Open the inlet and outlet shut-off valves on the assembly (C and D) and all testcocks. After draining, leave them half open and half closed (45 degrees).
  3. If you are blowing out the downstream system, make sure outlet drain valve (E) is open and the assembly outlet shut-off (D) is closed.
  4. Connect air to outlet drain valve (E) and clear the downstream system.
  5. After the blowout, set shut-offs C and D to half open and half closed (45 degrees).
  6. Leave drain valves (B and E), testcocks and ball or gate valves (C and D) half open and half closed for the winter.

The manual’s notice: keep the main shut-off (A) closed all winter. Rain Bird recommends an irrigation specialist for compressed-air blowouts because of the safety risks (Rain Bird).

How to Drain a Zurn Wilkins 720A for Winter

From the “Drain Procedure for Freeze Protection” in Zurn’s 720A instructions (Zurn Wilkins 720A). Numbers match the valve labels in that sheet.

  1. Turn off the main shut-off (1).
  2. Open the inlet and outlet drain valves (2 and 6). Open the PVB inlet and outlet shut-offs (3 and 5) and all test cocks. Leave all of them half open and half closed (45 degrees).
  3. If blowing out the system, make sure outlet drain (6) is open and PVB shut-off (5) is closed.
  4. Connect an air hose to outlet drain (6) and inject enough air to clear the downstream system.
  5. After the blowout, set outlet shut-off (5) and outlet drain (6) to half open and half closed (45 degrees).
  6. If there are no drain valves (2 and 6) and you are not blowing out the system, remove the PVB internals for the winter.
  7. Leave drains, shut-offs and test cocks half open and half closed (45 degrees) for the winter.

Zurn’s caution: make sure the main shut-off (1) stays tightly closed all winter so the system cannot refill, and that it seals without leaking.

Read the full procedure in the Zurn sheet before you start. If your PVB has no drain valves on either side, step 6 is Zurn’s answer: take the internals out for winter, or have a pro do it.

Why the Valves Stay Half Open

It looks odd to leave a ball valve at 45 degrees, but FEBCO explains it: water trapped between the ball and the body of a fully open or fully closed ball valve can freeze and damage the valve (Watts/FEBCO 765). Half open lets that pocket drain. Both manuals above call for the same position on every shut-off, drain and test cock for the winter.

If Your Backflow Preventer Already Froze

We did not find a manufacturer procedure for a frozen PVB, so this is general practice. Close the irrigation shut-off, usually a brass gate or ball valve just after the tee where the irrigation line leaves the house supply (Rain Bird valve guide). That keeps the house on while the sprinkler side is isolated. Let the device thaw on its own, then look for cracks in the body, bonnet and test cocks. A cracked device gets replaced, not patched.

Replacing a backflow preventer is part of Monarch’s irrigation repair work, and our irrigation cost guide covers what drives the price. For the rest of the system, see how to winterize sprinklers in the High Desert, and for valves that leak after a freeze, sprinkler valve leaking. When to do all this each year is on the High Desert yard care calendar, and local freeze dates by station are in our frost dates and growing zones guide. The full cluster starts at the High Desert irrigation guide.

Backflow Freeze Protection FAQs

Is a backflow preventer cover enough to stop freezing?

A cover slows heat loss, but the manufacturers still call for draining. FEBCO says its 765 assemblies must be drained for the winter in areas where freezing temperatures may occur. A cover makes the most sense on top of a drained device, or on one you keep in service for winter watering.

Can I drain a backflow preventer through the test cocks?

Not a FEBCO 765. The FEBCO winterization sheet says the assembly can not be adequately drained through the testcocks, and it calls for drain valves on the inlet and outlet sides below the assembly.

Why do I leave the valves half open for winter?

Water trapped between the ball and the body of a fully open or fully closed ball valve can freeze and damage it, according to FEBCO. Leaving it at 45 degrees lets that water drain.

Can I wrap the whole backflow preventer in insulation?

Not the air vent. Zurn says not to block the air vent opening with insulation, and Rain Bird says not to block the air vents and drain outlets on backflow preventers.

My Rain Bird PVB has no manual. What should I do?

Check the model plate. A backflow parts seller lists the Rain Bird PVB as produced from 1982 to 1993, and we found no current Rain Bird manual for it. The drain idea is similar to the FEBCO 765 and Wilkins 720A, but without a manual it is safer to have an irrigation pro winterize or replace it.